Wire catalogue / UL PVC & SR-PVC Hook-Up Wire
UL10071 300 V 80 °C SR-PVC Hook-Up Wire
UL10071 300 V 80 °C hook-up wire, 18–30 AWG. O.D. 0.7–1.6 mm, stranded, 11 colours. UL E170689 cited. Quote on request.
UL · E170689 is cited for this line. Request the issued document before relying on it for a finished-product approval.
Request certificate or datasheet →UL10071 is a SR-PVC-insulated hook-up wire manufactured by Xinya Electronic Co., Ltd. It is rated 300 V, 80 °C. It is supplied in 13 recorded constructions spanning 18–30 AWG, with an overall diameter of 0.7–1.6 mm, cut to the length you order.
UL10071 at a glance
- 18–30 AWG, across 13 listed constructions
- Stranded conductor throughout the documented range
- Insulation wall 0.2–0.22 mm
- Overall diameter 0.7–1.6 mm
- Max. conductor resistance 23.2–381 Ω/km at 20 °C DC (roughly 7.1–116.1 Ω per 1,000 ft)
- Routine withstand test on every listed row: 2000 VAC, 1 min
How UL10071 compares with its nearest alternatives
UL10071 and UL10501 share the 300 V rating and 80 °C temperature rating. Overall diameter runs 0.7–1.6 mm for UL10071 against 0.75–2.7 mm for UL10501. UL10071 is the tighter of the two where harness space is limited. Insulation wall is 0.2–0.22 mm against 0.25–0.41 mm. Size coverage is 18–30 AWG against 14–30 AWG.
Conductor construction and selection
Every construction listed for UL10071 is a stranded conductor, which suits harnesses and assemblies that are flexed or routed around a bend. The resistance column gives the maximum permitted value for the conductor at 20 °C DC.
How to read the UL10071 table
“Insulation O.D. (mm)” is measured over the insulation, not over a jacket, tape or braid. Conductor resistance is stated at 20 °C DC per kilometre — divide by 3.281 for ohms per 1,000 ft. The withstand column is a routine production test applied to finished lengths, not a continuous working voltage.
Questions buyers ask about UL10071
Which sizes of UL10071 are available?
18–30 AWG, across the 13 constructions in the table below. Sizes outside the table can be quoted on request.
Is UL10071 a stranded conductor?
Every construction documented for this line is stranded. Confirm the strand count you need — the “n/mm” figure in the table — because resistance and flexibility both depend on it, and two rows at the same size can differ.
What overall diameter does UL10071 run to?
The documented range is 0.7–1.6 mm. Quote the size, not the style alone, when the diameter has to fit a specific gland, grommet or channel.
Detailed specification table
Manufacturer construction data for UL10071. Values are transcribed from the source specification sheet. Confirm the final construction and order requirements during quotation.
Scroll horizontally to view all specifications
| AWG | Construction | Conductor diameter (mm) | Insulation thickness (mm) | Insulation O.D. (mm) | Max. conductor resistance (Ω/km, 20°C, DC) | Dielectric strength (VAC, 1 min) |
|---|---|---|---|---|---|---|
| 30 | 7/0.10 | 0.30 | 0.20 | 0.70 | 381 | 2000 |
| 28 | 7/0.127 | 0.38 | 0.21 | 0.80 | 239 | 2000 |
| 28 | 7/0.127 OS-1* | 0.38 | 0.21 | 0.80 | 239 | 2000 |
| 26 | 7/0.16 | 0.48 | 0.21 | 0.90 | 150 | 2000 |
| 26 | 7/0.16 OS-1* | 0.48 | 0.21 | 0.90 | 150 | 2000 |
| 24 | 7/0.20 | 0.60 | 0.20 | 1.00 | 94.2 | 2000 |
| 24 | 7/0.20 OS-1* | 0.60 | 0.20 | 1.00 | 94.2 | 2000 |
| 22 | 7/0.254 | 0.76 | 0.22 | 1.20 | 59.4 | 2000 |
| 22 | 7/0.254 OS-1* | 0.76 | 0.22 | 1.20 | 59.4 | 2000 |
| 20 | 7/0.32 | 0.96 | 0.22 | 1.40 | 36.7 | 2000 |
| 20 | 7/0.32 OS-1* | 0.96 | 0.22 | 1.40 | 36.7 | 2000 |
| 18 | 16/0.254 | 1.47 | 0.21 | 1.60 | 23.2 | 2000 |
| 18 | 7/0.404 OS-1* | 1.20 | 0.20 | 1.60 | 23.2 | 2000 |
Source specification sheet: 10071.