Wire catalogue / UL PVC & SR-PVC Hook-Up Wire
UL11079 150 V 80 °C PVC Hook-Up Wire
UL11079 150 V 80 °C hook-up wire, 26–32 AWG. O.D. 0.65–0.9 mm, stranded, 11 colours. UL E170689 cited. Quote on request.
UL · E170689 is cited for this line. Request the issued document before relying on it for a finished-product approval.
Request certificate or datasheet →UL11079 is a PVC-insulated hook-up wire manufactured by Xinya Electronic Co., Ltd. It is rated 150 V, 80 °C. It is supplied in 6 recorded constructions spanning 26–32 AWG, with an overall diameter of 0.65–0.9 mm, cut to the length you order.
UL11079 at a glance
- 26–32 AWG, across 6 listed constructions
- Stranded conductor throughout the documented range
- Insulation wall 0.2–0.21 mm
- Overall diameter 0.65–0.9 mm
- Max. conductor resistance 150–595 Ω/km at 20 °C DC (roughly 45.7–181.4 Ω per 1,000 ft)
- Routine withstand test on every listed row: 1500 VAC, 1 min
How UL11079 compares with its nearest alternatives
UL11079 and UL10272 share the 150 V rating and 80 °C temperature rating. Overall diameter runs 0.65–0.9 mm for UL11079 against 0.65–1.4 mm for UL10272. UL11079 is the tighter of the two where harness space is limited. Size coverage is 26–32 AWG against 20–32 AWG.
UL11079 and UL1061 share the 80 °C temperature rating and PVC insulation. The distinction is in voltage rating (150 V against 300 V). Overall diameter runs 0.65–0.9 mm for UL11079 against 0.75–2.7 mm for UL1061. UL11079 is the tighter of the two where harness space is limited. Insulation wall is 0.2–0.21 mm against 0.25–0.41 mm.
Conductor construction and selection
Every construction listed for UL11079 is a stranded conductor, which suits harnesses and assemblies that are flexed or routed around a bend. The resistance column gives the maximum permitted value for the conductor at 20 °C DC.
How to read the UL11079 table
“Insulation O.D. (mm)” is measured over the insulation, not over a jacket, tape or braid. Conductor resistance is stated at 20 °C DC per kilometre — divide by 3.281 for ohms per 1,000 ft. The withstand column is a routine production test applied to finished lengths, not a continuous working voltage.
Questions buyers ask about UL11079
Which sizes of UL11079 are available?
26–32 AWG, across the 6 constructions in the table below. Sizes outside the table can be quoted on request.
Is UL11079 a stranded conductor?
Every construction documented for this line is stranded. Confirm the strand count you need — the “n/mm” figure in the table — because resistance and flexibility both depend on it, and two rows at the same size can differ.
What overall diameter does UL11079 run to?
The documented range is 0.65–0.9 mm. Quote the size, not the style alone, when the diameter has to fit a specific gland, grommet or channel.
Detailed specification table
Manufacturer construction data for UL11079. Values are transcribed from the source specification sheet. Confirm the final construction and order requirements during quotation.
Scroll horizontally to view all specifications
| AWG | Construction | Conductor diameter (mm) | Insulation thickness (mm) | Insulation O.D. (mm) | Max. conductor resistance (Ω/km, 20°C, DC) | Dielectric strength (VAC, 1 min) |
|---|---|---|---|---|---|---|
| 32 | 7/0.08 | 0.24 | 0.20 | 0.65 | 595 | 1500 |
| 30 | 7/0.10 | 0.30 | 0.20 | 0.70 | 381 | 1500 |
| 28 | 7/0.127 | 0.38 | 0.21 | 0.80 | 239 | 1500 |
| 28 | 7/0.127 OS-1* | 0.38 | 0.21 | 0.80 | 239 | 1500 |
| 26 | 7/0.16 | 0.48 | 0.21 | 0.90 | 150 | 1500 |
| 26 | 7/0.16 OS-1* | 0.48 | 0.21 | 0.90 | 150 | 1500 |
Source specification sheet: 11079.
Request a quote for this line
Tell us the style, AWG, colour and quantity — or attach nothing and just describe the requirement. We reply to every enquiry.