Wire catalogue / UL PVC & SR-PVC Hook-Up Wire
UL10913 300 V 80 °C PVC Hook-Up Wire
UL10913 300 V 80 °C hook-up wire, 16–32 AWG. O.D. 1.25–2.55 mm, stranded. UL E170689 cited. Quote on request.
UL · E170689 is cited for this line. Request the issued document before relying on it for a finished-product approval.
Request certificate or datasheet →UL10913 is a PVC-insulated hook-up wire manufactured by Xinya Electronic Co., Ltd. It is rated 300 V, 80 °C. It is supplied in 9 recorded constructions spanning 16–32 AWG, with an overall diameter of 1.25–2.55 mm, cut to the length you order.
UL10913 at a glance
- 16–32 AWG, across 9 listed constructions
- Stranded conductor throughout the documented range
- Insulation wall 0.46 mm
- Overall diameter 1.25–2.55 mm
- Max. conductor resistance 14.6–595 Ω/km at 20 °C DC (roughly 4.5–181.4 Ω per 1,000 ft)
- Routine withstand test on every listed row: 2000 VAC, 1 min
How UL10913 compares with its nearest alternatives
UL10913 and UL1007 share the 300 V rating and 80 °C temperature rating. Overall diameter runs 1.25–2.55 mm for UL10913 against 1–2.4 mm for UL1007. UL1007 is the tighter of the two, so UL10913 is the option to take only when the larger diameter is acceptable. Insulation wall is 0.46 mm against 0.39–0.47 mm.
UL10913 and UL1095 share the 300 V rating and 80 °C temperature rating. Overall diameter runs 1.25–2.55 mm for UL10913 against 0.9–2.25 mm for UL1095. UL1095 is the tighter of the two, so UL10913 is the option to take only when the larger diameter is acceptable. Insulation wall is 0.46 mm against 0.32–0.39 mm. Size coverage is 16–32 AWG against 16–30 AWG.
Conductor construction and selection
Every construction listed for UL10913 is a stranded conductor, which suits harnesses and assemblies that are flexed or routed around a bend. The resistance column gives the maximum permitted value for the conductor at 20 °C DC.
How to read the UL10913 table
“Insulation O.D. (mm)” is measured over the insulation, not over a jacket, tape or braid. Conductor resistance is stated at 20 °C DC per kilometre — divide by 3.281 for ohms per 1,000 ft. The withstand column is a routine production test applied to finished lengths, not a continuous working voltage.
Questions buyers ask about UL10913
Which sizes of UL10913 are available?
16–32 AWG, across the 9 constructions in the table below. Sizes outside the table can be quoted on request.
Is UL10913 a stranded conductor?
Every construction documented for this line is stranded. Confirm the strand count you need — the “n/mm” figure in the table — because resistance and flexibility both depend on it, and two rows at the same size can differ.
What overall diameter does UL10913 run to?
The documented range is 1.25–2.55 mm. Quote the size, not the style alone, when the diameter has to fit a specific gland, grommet or channel.
Detailed specification table
Manufacturer construction data for UL10913. Values are transcribed from the source specification sheet. Confirm the final construction and order requirements during quotation.
Scroll horizontally to view all specifications
| AWG | Construction | Conductor diameter (mm) | Insulation thickness (mm) | Insulation O.D. (mm) | Max. conductor resistance (Ω/km, 20°C, DC) | Dielectric strength (VAC, 1 min) |
|---|---|---|---|---|---|---|
| 32 | 7/0.08 | 0.24 | 0.46 | 1.25 | 595 | 2000 |
| 30 | 7/0.10 | 0.30 | 0.46 | 1.35 | 381 | 2000 |
| 28 | 7/0.127 | 0.38 | 0.46 | 1.40 | 239 | 2000 |
| 26 | 7/0.16 | 0.48 | 0.46 | 1.50 | 150 | 2000 |
| 24 | 11/0.16 | 0.61 | 0.46 | 1.65 | 94.2 | 2000 |
| 22 | 17/0.16 | 0.76 | 0.46 | 1.75 | 59.4 | 2000 |
| 20 | 26/0.16 | 0.94 | 0.46 | 1.90 | 36.7 | 2000 |
| 18 | 41/0.16 | 1.18 | 0.46 | 2.20 | 23.2 | 2000 |
| 16 | 26/0.254 | 1.49 | 0.46 | 2.55 | 14.6 | 2000 |
Source specification sheet: 10913.
Request a quote for this line
Tell us the style, AWG, colour and quantity — or attach nothing and just describe the requirement. We reply to every enquiry.