Wire catalogue / UL PVC & SR-PVC Hook-Up Wire
UL2095 SR-PVC Shielded Multi-Conductor Cable
UL2095 multi-conductor cable, 18–30 AWG. O.D. 2.6–7.4 mm, stranded, up to 8 cores, shielded. UL E170689 cited. Quote on request.
UL · E170689 is cited for this line. Request the issued document before relying on it for a finished-product approval.
Request certificate or datasheet →UL2095 is a SR-PVC-insulated multi-conductor cable manufactured by Xinya Electronic Co., Ltd. The catalogue describes it as a shielded construction. It is supplied in 49 recorded constructions spanning 18–30 AWG, with an overall diameter of 2.6–7.4 mm, cut to the length you order.
UL2095 at a glance
- 18–30 AWG, across 49 listed constructions
- Stranded conductor throughout the documented range
- Insulation wall 0.25–0.31 mm
- Overall diameter 2.6–7.4 mm
- Max. conductor resistance 23.2–381 Ω/km at 20 °C DC (roughly 7.1–116.1 Ω per 1,000 ft)
- All 49 listed rows carry a shield (Al-mylar)
How UL2095 compares with its nearest alternatives
UL2095 and UL2547 share the SR-PVC insulation. Overall diameter runs 2.6–7.4 mm for UL2095 against 2.6–5.3 mm for UL2547. UL2547 is the tighter of the two, so UL2095 is the option to take only when the larger diameter is acceptable.
UL2095 and UL2096 sit in the same catalogue group but are rated differently. Overall diameter runs 2.6–7.4 mm for UL2095 against 3.2–8.4 mm for UL2096. UL2095 is the tighter of the two where harness space is limited. Insulation wall is 0.25–0.31 mm against 0.4–0.46 mm.
Conductor, core count and shielding
Every construction listed for UL2095 is a stranded conductor, which suits harnesses and assemblies that are flexed or routed around a bend. The resistance column gives the maximum permitted value for the conductor at 20 °C DC.
Core counts run from 2 to 8 in the documented range. Overall diameter grows with core count, so the figure to quote for gland, grommet and connector selection is the finished-cable diameter column rather than the single-core insulation diameter.
How to read the UL2095 table
“Insulation O.D. (mm)” is measured over the insulation, not over a jacket, tape or braid. “Jacket O.D. (mm)” is the finished cable diameter, which is the value to quote for gland, grommet and connector sizing. Conductor resistance is stated at 20 °C DC per kilometre — divide by 3.281 for ohms per 1,000 ft.
Questions buyers ask about UL2095
Which sizes of UL2095 are available?
18–30 AWG, across the 49 constructions in the table below. Sizes outside the table can be quoted on request.
Is UL2095 a stranded conductor?
Every construction documented for this line is stranded. Confirm the strand count you need — the “n/mm” figure in the table — because resistance and flexibility both depend on it, and two rows at the same size can differ.
What overall diameter does UL2095 run to?
The documented range is 2.6–7.4 mm. Quote the size, not the style alone, when the diameter has to fit a specific gland, grommet or channel.
Detailed specification table
Manufacturer construction data for UL2095. Values are transcribed from the source specification sheet and its continuation table. Confirm the final construction and order requirements during quotation.
Scroll horizontally to view all specifications
| AWG | Construction | Conductor diameter (mm) | Core count | Insulation thickness (mm) | Insulation O.D. (mm) | Shield | Jacket thickness (mm) | Jacket O.D. (mm) | Max. conductor resistance (Ω/km, 20°C, DC) |
|---|---|---|---|---|---|---|---|---|---|
| 30 | 7/0.10 | 0.30 | 2 | 0.25 | 0.80 | Al-mylar | 0.45 | 2.60 | 381 |
| 30 | 7/0.10 | 0.30 | 3 | 0.25 | 0.80 | Al-mylar | 0.49 | 2.80 | 381 |
| 30 | 7/0.10 | 0.30 | 4 | 0.25 | 0.80 | Al-mylar | 0.48 | 3.00 | 381 |
| 30 | 7/0.10 | 0.30 | 5 | 0.25 | 0.80 | Al-mylar | 0.47 | 3.20 | 381 |
| 30 | 7/0.10 | 0.30 | 6 | 0.25 | 0.80 | Al-mylar | 0.45 | 3.40 | 381 |
| 30 | 7/0.10 | 0.30 | 7 | 0.25 | 0.80 | Al-mylar | 0.45 | 3.40 | 381 |
| 30 | 7/0.10 | 0.30 | 8 | 0.25 | 0.80 | Al-mylar | 0.48 | 3.70 | 381 |
| 28 | 7/0.127 | 0.38 | 2 | 0.26 | 0.90 | Al-mylar | 0.45 | 2.80 | 239 |
| 28 | 7/0.127 | 0.38 | 3 | 0.26 | 0.90 | Al-mylar | 0.48 | 3.00 | 239 |
| 28 | 7/0.127 | 0.38 | 4 | 0.26 | 0.90 | Al-mylar | 0.46 | 3.20 | 239 |
| 28 | 7/0.127 | 0.38 | 5 | 0.26 | 0.90 | Al-mylar | 0.49 | 3.50 | 239 |
| 28 | 7/0.127 | 0.38 | 6 | 0.26 | 0.90 | Al-mylar | 0.45 | 3.70 | 239 |
| 28 | 7/0.127 | 0.38 | 7 | 0.26 | 0.90 | Al-mylar | 0.45 | 3.70 | 239 |
| 28 | 7/0.127 | 0.38 | 8 | 0.26 | 0.90 | Al-mylar | 0.47 | 4.00 | 239 |
| 26 | 7/0.16 | 0.48 | 2 | 0.26 | 1.00 | Al-mylar | 0.45 | 3.00 | 150 |
| 26 | 7/0.16 | 0.48 | 3 | 0.26 | 1.00 | Al-mylar | 0.47 | 3.20 | 150 |
| 26 | 7/0.16 | 0.48 | 4 | 0.26 | 1.00 | Al-mylar | 0.49 | 3.50 | 150 |
| 26 | 7/0.16 | 0.48 | 5 | 0.26 | 1.00 | Al-mylar | 0.45 | 3.70 | 150 |
| 26 | 7/0.16 | 0.48 | 6 | 0.26 | 1.00 | Al-mylar | 0.45 | 4.00 | 150 |
| 26 | 7/0.16 | 0.48 | 7 | 0.26 | 1.00 | Al-mylar | 0.45 | 4.00 | 150 |
| 26 | 7/0.16 | 0.48 | 8 | 0.26 | 1.00 | Al-mylar | 0.45 | 4.30 | 150 |
| 24 | 11/0.16 | 0.61 | 2 | 0.25 | 1.10 | Al-mylar | 0.45 | 3.20 | 94.2 |
| 24 | 11/0.16 | 0.61 | 3 | 0.25 | 1.10 | Al-mylar | 0.47 | 3.40 | 94.2 |
| 24 | 11/0.16 | 0.61 | 4 | 0.25 | 1.10 | Al-mylar | 0.47 | 3.70 | 94.2 |
| 24 | 11/0.16 | 0.61 | 5 | 0.25 | 1.10 | Al-mylar | 0.47 | 4.00 | 94.2 |
| 24 | 11/0.16 | 0.61 | 6 | 0.25 | 1.10 | Al-mylar | 0.45 | 4.30 | 94.2 |
| 24 | 11/0.16 | 0.61 | 7 | 0.25 | 1.10 | Al-mylar | 0.45 | 4.30 | 94.2 |
| 24 | 11/0.16 | 0.61 | 8 | 0.25 | 1.10 | Al-mylar | 0.49 | 4.70 | 94.2 |
| 22 | 17/0.16 | 0.76 | 2 | 0.27 | 1.30 | Al-mylar | 0.45 | 3.60 | 59.4 |
| 22 | 17/0.16 | 0.76 | 3 | 0.27 | 1.30 | Al-mylar | 0.45 | 3.80 | 59.4 |
| 22 | 17/0.16 | 0.76 | 4 | 0.27 | 1.30 | Al-mylar | 0.48 | 4.20 | 59.4 |
| 22 | 17/0.16 | 0.76 | 5 | 0.27 | 1.30 | Al-mylar | 0.49 | 4.60 | 59.4 |
| 22 | 17/0.16 | 0.76 | 6 | 0.27 | 1.30 | Al-mylar | 0.45 | 4.90 | 59.4 |
| 22 | 17/0.16 | 0.76 | 7 | 0.27 | 1.30 | Al-mylar | 0.45 | 4.90 | 59.4 |
| 22 | 17/0.16 | 0.76 | 8 | 0.27 | 1.30 | Al-mylar | 0.56 | 5.50 | 59.4 |
| 20 | 26/0.16 | 0.94 | 2 | 0.28 | 1.50 | Al-mylar | 0.45 | 4.00 | 36.7 |
| 20 | 26/0.16 | 0.94 | 3 | 0.28 | 1.50 | Al-mylar | 0.48 | 4.30 | 36.7 |
| 20 | 26/0.16 | 0.94 | 4 | 0.28 | 1.50 | Al-mylar | 0.49 | 4.70 | 36.7 |
| 20 | 26/0.16 | 0.94 | 5 | 0.28 | 1.50 | Al-mylar | 0.58 | 5.30 | 36.7 |
| 20 | 26/0.16 | 0.94 | 6 | 0.28 | 1.50 | Al-mylar | 0.55 | 5.70 | 36.7 |
| 20 | 26/0.16 | 0.94 | 7 | 0.28 | 1.50 | Al-mylar | 0.55 | 5.70 | 36.7 |
| 20 | 26/0.16 | 0.94 | 8 | 0.28 | 1.50 | Al-mylar | 0.58 | 6.20 | 36.7 |
| 18 | 41/0.16 | 1.18 | 2 | 0.31 | 1.80 | Al-mylar | 0.45 | 4.60 | 23.2 |
| 18 | 41/0.16 | 1.18 | 3 | 0.31 | 1.80 | Al-mylar | 0.46 | 4.90 | 23.2 |
| 18 | 41/0.16 | 1.18 | 4 | 0.31 | 1.80 | Al-mylar | 0.53 | 5.50 | 23.2 |
| 18 | 41/0.16 | 1.18 | 5 | 0.31 | 1.80 | Al-mylar | 0.57 | 6.10 | 23.2 |
| 18 | 41/0.16 | 1.18 | 6 | 0.31 | 1.80 | Al-mylar | 0.60 | 6.70 | 23.2 |
| 18 | 41/0.16 | 1.18 | 7 | 0.31 | 1.80 | Al-mylar | 0.60 | 6.70 | 23.2 |
| 18 | 41/0.16 | 1.18 | 8 | 0.31 | 1.80 | Al-mylar | 0.68 | 7.40 | 23.2 |
Source specification sheet: 2095, 209502.
Request a quote for this line
Tell us the style, AWG, colour and quantity — or attach nothing and just describe the requirement. We reply to every enquiry.