Wire catalogue / UL XLPE & High-Temperature Hook-Up Wire
UL11027 300 V 105 °C mPPE Hook-Up Wire
UL11027 300 V 105 °C hook-up wire, 20–28 AWG. O.D. 0.85–1.5 mm, solid and stranded. UL E170689 cited. Quote on request.
UL · E170689 is cited for this line. Request the issued document before relying on it for a finished-product approval.
Request certificate or datasheet →UL11027 is a mPPE-insulated hook-up wire manufactured by Xinya Electronic Co., Ltd. It is rated 300 V, 105 °C. It is supplied in 15 recorded constructions spanning 20–28 AWG, with an overall diameter of 0.85–1.5 mm, cut to the length you order.
UL11027 at a glance
- 20–28 AWG, across 15 listed constructions
- Both solid (single-strand) and stranded conductors are listed — 5 solid and 10 stranded
- Insulation wall 0.25–0.27 mm
- Overall diameter 0.85–1.5 mm
- Max. conductor resistance 35.2–239 Ω/km at 20 °C DC (roughly 10.7–72.8 Ω per 1,000 ft)
- Routine withstand test on every listed row: 2000 VAC, 1 min
How UL11027 compares with its nearest alternatives
UL11027 and UL10368 share the 300 V rating and 105 °C temperature rating. Overall diameter runs 0.85–1.5 mm for UL11027 against 0.75–4.2 mm for UL10368. UL11027 is the tighter of the two where harness space is limited. Size coverage is 20–28 AWG against 10–30 AWG.
UL11027 and UL3567 share the 300 V rating and 105 °C temperature rating. Overall diameter runs 0.85–1.5 mm for UL11027 against 1.05–2.7 mm for UL3567. UL11027 is the tighter of the two where harness space is limited. Insulation wall is 0.25–0.27 mm against 0.39–0.47 mm. Size coverage is 20–28 AWG against 14–30 AWG.
Conductor construction and selection
Both conductor families are listed. Single-strand rows such as 1/0.32 at 28 AWG suit fixed routing and insulation-displacement termination, where the conductor is not flexed after installation. Stranded rows such as 7/0.127 at 28 AWG flex repeatedly and are the usual choice for hand-soldered harnesses and anything that has to follow a moving path. Conductor resistance is the same at a given size, so the choice between them is mechanical rather than electrical.
How to read the UL11027 table
“Insulation O.D. (mm)” is measured over the insulation, not over a jacket, tape or braid. Conductor resistance is stated at 20 °C DC per kilometre — divide by 3.281 for ohms per 1,000 ft. The withstand column is a routine production test applied to finished lengths, not a continuous working voltage.
Questions buyers ask about UL11027
Which sizes of UL11027 are available?
20–28 AWG, across the 15 constructions in the table below. Sizes outside the table can be quoted on request.
Can UL11027 be supplied in both solid and stranded conductor?
Yes. The documented range covers 15 constructions, of which 5 are single-strand and 10 are stranded. Give the construction, not only the AWG, when you request a quotation.
What overall diameter does UL11027 run to?
The documented range is 0.85–1.5 mm. Quote the size, not the style alone, when the diameter has to fit a specific gland, grommet or channel.
Detailed specification table
Manufacturer construction data for UL11027. Values are transcribed from the source specification sheet. Confirm the final construction and order requirements during quotation.
Scroll horizontally to view all specifications
| AWG | Construction | Conductor diameter (mm) | Insulation thickness (mm) | Insulation O.D. (mm) | Max. conductor resistance (Ω/km, 20°C, DC) | Dielectric strength (VAC, 1 min) |
|---|---|---|---|---|---|---|
| 28 | 1/0.32 | 0.32 | 0.27 | 0.85 | 227 | 2000 |
| 28 | 7/0.127 | 0.38 | 0.26 | 0.90 | 239 | 2000 |
| 28 | 7/0.127 OS-1* | 0.38 | 0.26 | 0.90 | 239 | 2000 |
| 26 | 1/0.404 | 0.40 | 0.25 | 0.90 | 143 | 2000 |
| 26 | 7/0.16 | 0.48 | 0.26 | 1.00 | 150 | 2000 |
| 26 | 7/0.16 OS-1* | 0.48 | 0.26 | 1.00 | 150 | 2000 |
| 24 | 1/0.511 | 0.51 | 0.25 | 1.00 | 89.3 | 2000 |
| 24 | 7/0.20 | 0.60 | 0.25 | 1.10 | 94.2 | 2000 |
| 24 | 7/0.20 OS-1* | 0.60 | 0.25 | 1.10 | 94.2 | 2000 |
| 22 | 1/0.643 | 0.64 | 0.25 | 1.15 | 56.4 | 2000 |
| 22 | 7/0.254 | 0.76 | 0.27 | 1.30 | 59.4 | 2000 |
| 22 | 7/0.254 OS-1* | 0.76 | 0.27 | 1.30 | 59.4 | 2000 |
| 20 | 1/0.813 | 0.81 | 0.27 | 1.35 | 35.2 | 2000 |
| 20 | 7/0.32 | 0.96 | 0.27 | 1.50 | 36.7 | 2000 |
| 20 | 7/0.32 OS-1* | 0.96 | 0.27 | 1.50 | 36.7 | 2000 |
Source specification sheet: 11027.