Wire catalogue / UL XLPE & High-Temperature Hook-Up Wire
UL1792 30 V 80 °C Shielded PE Low-Voltage Wire
UL1792 30 V 80 °C hook-up wire, 22–22 AWG. O.D. 1.9–3.3 mm, solid and stranded, shielded. UL E170689 cited. Quote on request.
UL · E170689 is cited for this line. Request the issued document before relying on it for a finished-product approval.
Request certificate or datasheet →UL1792 is a PE-insulated hook-up wire manufactured by Xinya Electronic Co., Ltd. It is rated 30 V, 80 °C. The catalogue describes it as a shielded construction. It is supplied in 7 recorded constructions spanning 22–22 AWG, with an overall diameter of 1.9–3.3 mm, cut to the length you order.
UL1792 at a glance
- 22–22 AWG, across 7 listed constructions
- Both solid (single-strand) and stranded conductors are listed — 3 solid and 4 stranded
- Insulation wall 0.32–0.8 mm
- Overall diameter 1.9–3.3 mm
- Max. conductor resistance 56.4–56.4 Ω/km at 20 °C DC (roughly 17.2–17.2 Ω per 1,000 ft)
- All 7 listed rows carry a shield (26/0.10, 32/0.10, 34/0.10)
How UL1792 compares with its nearest alternatives
UL1792 and UL1589 share the 30 V rating and 80 °C temperature rating. Overall diameter runs 1.9–3.3 mm for UL1792 against 0.65–1.3 mm for UL1589. UL1589 is the tighter of the two, so UL1792 is the option to take only when the larger diameter is acceptable. Insulation wall is 0.32–0.8 mm against 0.19–0.27 mm. Size coverage is 22–22 AWG against 22–30 AWG.
Conductor construction and selection
Both conductor families are listed. Single-strand rows such as 1/0.254 at 22 AWG suit fixed routing and insulation-displacement termination, where the conductor is not flexed after installation. Stranded rows such as 7/0.10 at 22 AWG flex repeatedly and are the usual choice for hand-soldered harnesses and anything that has to follow a moving path. Conductor resistance is the same at a given size, so the choice between them is mechanical rather than electrical.
How to read the UL1792 table
“Insulation O.D. (mm)” is measured over the insulation, not over a jacket, tape or braid. “Jacket O.D. (mm)” is the finished cable diameter, which is the value to quote for gland, grommet and connector sizing. Conductor resistance is stated at 20 °C DC per kilometre — divide by 3.281 for ohms per 1,000 ft.
Questions buyers ask about UL1792
Which sizes of UL1792 are available?
22–22 AWG, across the 7 constructions in the table below. Sizes outside the table can be quoted on request.
Can UL1792 be supplied in both solid and stranded conductor?
Yes. The documented range covers 7 constructions, of which 3 are single-strand and 4 are stranded. Give the construction, not only the AWG, when you request a quotation.
What overall diameter does UL1792 run to?
The documented range is 1.9–3.3 mm. Quote the size, not the style alone, when the diameter has to fit a specific gland, grommet or channel.
Detailed specification table
Manufacturer construction data for UL1792. Values are transcribed from the source specification sheet. Confirm the final construction and order requirements during quotation.
Scroll horizontally to view all specifications
| AWG | Construction | Conductor diameter (mm) | Insulation thickness (mm) | Insulation O.D. (mm) | Shield / spiral construction | Jacket thickness (mm) | Jacket O.D. (mm) | Max. conductor resistance (Ω/km, 20°C, DC) |
|---|---|---|---|---|---|---|---|---|
| 22 | 1/0.254 | 0.25 | 0.32 | 0.90 | 26/0.10 | 0.40 | 1.90 | 56.4 |
| 22 | 7/0.10 | 0.30 | 0.40 | 1.10 | 32/0.10 | 0.40 | 2.10 | 56.4 |
| 22 | 1/0.32 | 0.32 | 0.44 | 1.20 | 34/0.10 | 0.40 | 2.20 | 56.4 |
| 22 | 7/0.127 | 0.38 | 0.51 | 1.40 | 40/0.10 | 0.40 | 2.40 | 56.4 |
| 22 | 1/0.404 | 0.40 | 0.55 | 1.50 | 42/0.10 | 0.40 | 2.50 | 56.4 |
| 22 | 7/0.16 | 0.48 | 0.61 | 1.70 | 47/0.10 | 0.40 | 2.70 | 56.4 |
| 22 | 11/0.16 | 0.61 | 0.80 | 2.20 | 51/0.12 | 0.43 | 3.30 | 56.4 |
Source specification sheet: 1792.
Request a quote for this line
Tell us the style, AWG, colour and quantity — or attach nothing and just describe the requirement. We reply to every enquiry.