Skip to content
Authorized Suzhou distributor · Xinya Electronic Co., Ltd. 📞 +86 15862457677 📫 [email protected]
Xinya AWM Wire Authorized Suzhou distributor · Xinya Electronic Co., Ltd.

Xinya Blog  / Nov 18, 2026

How to Specify IP67 and IP68 Sealed Wire Harnesses

By the Xinya wire harness engineering team · Published Nov 18, 2026 · Last updated Nov 18, 2026

IP67 protects a sealed wire harness against dust and 30 minutes of immersion in 1 m of water, while IP68 requires continuous immersion at a depth and duration you agree with the manufacturer — commonly 1.5 m for 30 minutes or 3 m for 24 hours. The rating applies to the assembly, not the connector alone.

That last sentence is where most sealing projects fail. A buyer specifies an IP68 connector, receives the harness, and finds water inside the housing three months later — because the jacket, the crimp, the wire ends and the overmould were never part of one sealing plan. In a harness, the enclosure is a system of five or six interfaces.

Suzhou Fuxi Electromechanical Equipment Co., Ltd. (Xinya) is a wire harness manufacturer founded in 2008 and an authorised distributor of Xinya Electronic Co., Ltd., so we see both halves of the problem: the connector on the drawing and the wire that feeds it. This guide covers what each rating tests, where ingress really happens, and how to write an unambiguous requirement.

What Do IP67 and IP68 Actually Mean for a Harness?

Both share a first digit of 6: dust tight, verified under a 20 mbar vacuum. They differ only in the water test. IPX7 is fixed — 1 m below the surface for 30 minutes. IPX8 has no fixed test; depth and duration are whatever the manufacturer and user agree, provided the test is more severe than IPX7.

That difference is commercial. Two suppliers can both claim IP68 while testing to 1.5 m for 30 minutes and 10 m for 24 hours. An IP68 claim without a stated depth and time is not a specification.

Rating Dust test Water test condition Typical harness use What to watch
IP66 Dust tight Powerful jets, 12.5 mm nozzle, 100 L/min, 3 min Outdoor enclosures, washdown cabinets Jet only — no immersion credit
IP67 Dust tight, 20 mbar vacuum 1 m immersion, 30 min Machine sensors, pump controls, outdoor junction boxes Open wire ends can still wick water
IP68 Dust tight Continuous immersion, depth and time agreed (e.g. 1.5 m / 30 min or 3 m / 24 h) EV battery packs, marine, sump-mounted sensors Depth and duration vary by supplier
IP69K Dust tight 80 °C jet, 80–100 bar, 12.5 L/min, four angles Food and pharmaceutical washdown Not a substitute for an immersion rating

IP69K is often mis-sold as “higher than IP68”. It tests a different stress: high-pressure hot jets at close range. A harness can pass IP69K and still flood in 2 m of standing water. If your application involves both washdown and pooling, specify and test both.

Where Does Water Actually Get Into a Sealed Harness?

The connector housing is rarely the first failure. Water arrives through four routes, and only the first is solved by buying a sealed connector series.

  • Capillary wicking through the conductor. Stranded wire is a bundle of gaps. Water entering a cut or crimped end travels along the interstices, sometimes over a metre, and exits at the far connector. This is the most common cause of “sealed” harness failures.
  • Unmated interfaces. Most ratings apply only in the mated condition. A connector left open during shipping or service has no seal at all.
  • Jacket-to-housing transitions. A gland or overmould that does not bond to the jacket leaves a path around the cable rather than through it. PVC and TPU behave very differently under the same potting compound.
  • Mechanical abuse at the seal. An over-torqued gland or a bend radius tighter than the cable allows opens a gap that passed the type test on a straight sample.

Blocking the conductor path is the step most often skipped: a sealed crimp carrying sealant into the barrel, a blocked-core cable, or a potted wire end. Any of the three works, none is free, and the drawing has to say which you want.

Which Sealing Method Fits Your IP67 or IP68 Requirement?

The method follows from volume, serviceability and how severe the immersion is — not from the rating number alone.

Sealing method Realistic rating Best fit Limitation
Sealed connector with individual wire seals IP67 Field-serviceable joints, sensor drops Every cavity needs its seal; one missing plug voids the joint
Cable gland with sealing washer IP66 to IP67 Panel and enclosure entries Torque-sensitive; thread must match wall thickness
Adhesive-lined heat shrink IP67 Splices, jacket transitions Adhesive flow depends on jacket polymer
Overmoulding in TPU or TPE IP67 to IP68 Volume production, integral strain relief Tooling cost; needs a jacket the moulding bonds to
Potting or epoxy-filled backshell IP68 Low volume, severe duty Not reworkable — a failed unit is scrap
Blocked-core cable plus sealed crimp IP68 Immersion with open wire ends Higher cable cost, larger bend radius

Most industrial projects reach IP67 with a sealed connector series, an adhesive-lined transition and a defined jacket — no tooling. Moving to IP68 usually means adding overmoulding or potting, and that decision belongs at quotation rather than after first article. Our over-moulded cable assembly line exists for exactly this step.

Can You Test IP68 Without Immersing Every Unit?

Yes, and you should not immerse production units at all. Immersion is a type test on samples; production is screened with a non-destructive pressure-decay leak test on 100% of units, typically charged to 0.3–0.5 bar, held 5–10 seconds, against a pass threshold agreed in mbar.

  1. Pre-conditioning. Ten thermal cycles between −40 °C and +125 °C, then immersion. IEC 60529 alone does not require cycling, which is why a harness can pass the standard and fail in service.
  2. Type test. IPX7 at 1 m / 30 min, or the agreed IPX8 depth and duration, in the mated condition stated on the drawing.
  3. Electrical checks before and after. Continuity on every circuit, insulation resistance at 500 VDC, and dielectric withstand at the voltage your specification calls for.
  4. Production screening. Pressure decay on every unit, with traceable results attached to the shipment.

Ask for the test report, not a certificate of compliance. The report shows depth, duration, mated state and pre-conditioning; a compliance statement shows none of it. Our wider test regime is summarised on the FAQ page, and the crimp variables that decide whether a seal holds are covered in terminal crimp quality.

What Should a Sealed Harness Drawing Specify?

Most sealing disputes are drawing defects, not manufacturing defects. Seven items remove the ambiguity.

  • Rating plus test condition. Write “IP68, 3 m / 24 h, IEC 60529”, never “IP68” alone.
  • Mated or unmated. State which condition is rated, and whether a protective cap ships with the harness.
  • Sealing method per interface. Connector seals, jacket transition, splice and wire-end treatment, individually.
  • Cable construction. Jacket polymer, outside diameter, core count, and whether the core must be blocked.
  • Medium and temperature. Fresh water, salt water, coolant and hydraulic oil are four different requirements.
  • Strain relief and routing. Minimum bend radius at the backshell and the cable exit angle.
  • Evidence. Type-test report, 100% pressure-decay data, and UV-resistant label material for outdoor builds.

If you have a drawing but no sealing detail, our harness specification checklist covers the wider document, and the harness builder produces a starting specification you can edit.

Does IP68 Cost Much More Than IP67?

Usually yes, but rarely because of the connector. Sealed connector families commonly cost two to four times their unsealed equivalents at the same pin count, and the jump to IP68 adds tooling, potting or a blocked-core cable on top.

Volume is the larger variable: overmoulding tooling is fixed and spreads across the order, so 50 pieces carry a very different unit cost from 5,000 of the same design. Where volume is low, potting or a gland seal often beats a mould. Two honest ways to cut cost — keep the sealed boundary small, and keep serviceable joints out of the immersed zone. The full anatomy is in wire harness cost factors.

Which Industries Use Sealed Harnesses, and How Do They Differ?

The rating is the same across sectors; the surrounding requirements are not.

  • Industrial automation. Coolant mist and washdown dominate, so a chemical-resistant jacket and flex life at the machine joint matter more than static immersion. See industrial control machine harnesses and the industrial automation page.
  • Marine, RV and off-road. Salt water, UV and vibration together; jacket and label ageing outpace the seal. See marine and RV harnesses.
  • EV and storage. IP67 or IP68 at the pack boundary, with the harness assembled before the pack is sealed. See EV battery harnesses.
  • Outdoor power. Twenty-year exposure, where connector sealing and housing UV stability outweigh the immersion figure. See solar harnesses.

Wire choice follows the same logic. A flexible industrial control cable survives repeated flexing at a gland where general-purpose hook-up wire cracks, so start from our UL flexible industrial control wire family or the shielded UL2587 drag-chain cable.

How Do You Qualify a Sealed Harness Supplier?

Five questions separate a supplier who can hold a seal from one who can quote one. Ask before the sample stage.

  1. What depth and duration do you test to for IP68, and in which mated condition?
  2. Is leak testing 100% pressure decay or sample immersion, and do I receive the data?
  3. How do you block capillary wicking at open wire ends?
  4. Which jacket polymers have you overmoulded or potted successfully, and which failed?
  5. What pre-conditioning precedes the immersion test?

Specific answers mean the supplier has done this before; “IP68 is standard for us” means they have not. Because we build to drawing and supply the wire, we answer the third question with a construction change rather than a disclaimer — a distinction that shows up in the field, as on our sensor and encoder cable assembly page.

Frequently Asked Questions

Is IP68 always better than IP67?

Only if your application is immersed longer or deeper than the IPX7 test. IP68 is defined by an agreed test, so a weak IP68 claim can be less demanding than a strict IP67 one. Compare the stated depth and duration, not the number.

Does an IP68 connector make my harness IP68?

No. The rating covers the assembly. Jacket, crimp sealing, wire-end treatment and the jacket-to-housing transition must all reach the same level, and most field failures trace to one of those rather than the connector.

Can a sealed harness be repaired in the field?

Sealed connector joints can be unmated and remated if seals and mating faces are clean and undamaged. Overmoulded and potted sections cannot be repaired — they are replaced as a unit, which is why repairability belongs in the original design decision.

What temperature range should a sealed harness be rated for?

State it explicitly. −40 °C to +125 °C is a common industrial envelope, but the seal, jacket and moulding compound each have their own limit and the lowest governs. Thermal cycling before immersion is what exposes a marginal design.

Do you supply the wire and the connector, or only assemble?

Both. As an authorised distributor of Xinya Electronic Co., Ltd. we supply UL, VDE, PSE, TUV, CE, RoHS and REACH wire styles, and build around customer-specified or equivalently sourced connectors. One source for wire and harness removes the argument about which side leaked.

How long does a sealed harness order take?

Common hook-up wire specifications such as UL1007, UL1015, UL1061 and UL1569 release quickly; other wire styles run around 7 days. Assemblies are scheduled by drawing, connector lead time and sealing method — overmoulded parts need tooling first.

Can I see the assembly process before ordering?

Yes. Our factory videos show crimping, assembly and inspection with subtitles, and a sample order is the normal way to confirm sealing and fit before volume.

Specify a Sealed Harness With Confidence

Send the drawing, the IP rating with its depth and duration, and the environment the harness will see. We will confirm the sealing method, cable construction and test evidence before anything is cut.

Build your harness specification or request a quote — typical response is one working day.

Need help selecting the right cable?

Send the style, voltage, temperature, size and application. We will confirm the construction and documentation available for the exact line.

Request a quote

Related wire selection guides

Related wire products

Questions & answers

Frequently asked questions

Certifications, lead time, payment, shipping and MOQ — the points buyers ask about most often. If something is still unclear, send us your requirement and we will answer directly. See the full FAQ →

01 Are you a manufacturer or a trading company?

We are a wire harness manufacturer — cutting, stripping, crimping, sealing and testing are all carried out in-house at our Suzhou plant. We are also an authorised distributor of Xinya brand electronic wire, so you can source both the wire and the finished harness from one supplier.

02 What certifications do your electronic wires have?

Our electronic wires carry UL, VDE, PSE and CE approvals, together with RoHS and REACH compliance for the European market; TUV approvals are available for PV and renewable-energy wire. Certificates and test reports are issued by the manufacturer and can be supplied with your quotation on request.

03 How long is the lead time?

For electronic wire, popular styles such as UL1007, UL1015, UL1061 and UL1569 are normally available quickly; other styles, non-standard colours and cut lengths usually take around 7 days. Wire harnesses are made to order, so the schedule depends on your drawing, connector availability and quantity — we confirm it in the quotation.

04 What are your payment terms?

We commonly accept T/T (telegraphic transfer), PayPal and Western Union. Typically a 30% deposit is required before production, with the balance paid before shipment.

05 How do you ship the goods?

Samples and small orders are shipped by international express (DHL, FedEx, UPS, TNT) or by air freight. Larger orders normally go by sea to reduce freight cost. We can quote EXW, FOB, CIF or door-to-door terms and will recommend the option that best fits your budget and delivery date.

06 Do you have a minimum order quantity (MOQ)?

We keep a low MOQ to support your business. Generally the MOQ is 1 piece for standard models, although it may vary slightly for customised products. Small trial orders are welcome.

07 Can you build harnesses to our own drawing or sample?

Yes. We build to print and build to sample — send us a 2D drawing, a BOM, connector part numbers or even a photo of the part in use, and we will assemble, test and quote accordingly.

08 Can I get a sample before placing a bulk order?

Yes. We are happy to build a prototype first so that you can approve the fit, crimp and finish before committing to volume. Send the drawing and the target quantity and we will quote sample cost and lead time.

09 What information do you need to give a quotation?

For wire: the style or UL number, AWG, voltage and temperature rating, insulation, conductor, colour and length. For harnesses: the drawing or BOM, connector brand and part number, terminal and housing type, wire specification, cut length and tolerance, sleeving or tubing, label and packaging requirements, quantity and destination. If anything is unclear we will ask — or propose a construction for you.

10 Do you support OEM / ODM and private labelling?

Yes. We work with customer-specified connectors and brands as well as JST, Molex and HongXing, and can add printed markers, custom labels, printed bags and your own carton artwork for OEM and ODM projects.

11 How do you control quality?

Every order goes through incoming wire inspection, cutting and stripping checks, crimp height and terminal pull-force testing, 100% continuity and open-and-short testing, and a final dimensional and visual inspection. Inspection records can be supplied with the shipment when your project requires them.

12 Can you help with wire and connector selection?

Yes — our engineers help match wire gauge, insulation and temperature rating to your current, voltage and working environment, and select a terminal and housing combination that crimps reliably. Describe the application or send a sample and we will propose a construction.

13 Can you supply cut lengths and custom packaging?

Yes. Wire can be supplied in cut lengths, coils or spools, with PE bags, cartons, pallets and printed labels arranged to suit your warehouse or production line.

14 Do you ship worldwide, and can I visit the factory?

We ship worldwide, with regular shipments to Europe, North America, South-East Asia, the Middle East and Australia. You are welcome to visit our plant in Suzhou, and you can see our production lines in the factory videos on this site.

15 What happens if there is a quality problem after delivery?

Contact us with the order or batch number and photos of the issue. We will check it against our production and inspection records and, where the fault is confirmed on our side, arrange replacement or credit.

Need wire to a specification?

Send the style, AWG range, colour and length — or your BOM and drawing. We will come back with construction, availability and lead time. This catalogue publishes no prices; every enquiry is quoted directly.

Request a quote